Exsenco U.S Contact For Santest

 

GYcAT

 

Photograph 3
The GYcAT probe receives the function which is almost equal to the GYFC controller to all probe head sections, DC24V power source just is supplied can obtain the analog signal of the high accuracy which is proportionate to magnetic position. The output signal 0 - 10V or the voltage output 10 - 0V is standard. 4 - 20mA or also the electric current output 20 - 4mA is possible with option. In addition, the warning function which inspects the abnormality of the magnet is had usually. You can expand application as a replacement of [potenshiyometa] and differential trance etc.
3
3
3
 
 

Specifications

3
Precision Linearity Below TYP ±0.05%FS
Resolution Below 0.01%FS
Repeatability Below ±0.01%FS
Temperature characteristic 40ppm FS/℃
Output Voltage output 0 - 10VDC or 10 - 0VDC load current Max5mA, load resistance Min2kΩ
Electric current output (option) 4 - 20mA or 20 - 4mA load resistance Max500Ω
Alarm output Open collector 30V 0.1A
Frequency characteristic Scanning frequency 1kHz (standard)
Power source and consumed electric current +24VDC±2V 0.1A
Environmental characteristic Resisting pressure 35MPa (probe rod)
Category temperature range -20℃ - +65℃
Storage temperature range -40℃ - +80℃
Resistance swing 6G (or 40Hz2mmPP)
Shock resistant 50G (2msec)
Protective standard IP65
* As for the magnet No.2P type belongs usually. 3

Type Variations

3
3
 
GYcAT-□□□□-□□-□-□
1 Effective stroke (mm)
3 150,200,250,300,350,400,500,700,1000,1250,1500,1750,2000
2 Output
3 A: 0 - 10V B: 4 - 20mA C: Bipolar in addition
2 Operational direction (to rod point when moving)
3 D: Increase operation R: Decrease operation
2 Installation screw
3 M: M24×P1 (standard) N: M18×P1.5 U: 3/4-16UNF
2 Cable removal
3 As for connector type non entry G*: [piguteiru] type (* cable length m)
3
3

External Dimensions Drawing

3
3 ●GYcAT probe
3
3 Material probe head: Aluminum alloy
   Probe rod: SUS304
GYcAT probe
personal identification number

Function

1 DC24V
2 NC
3 0V
4 SIG COM
5 Voltage output
6 (Electric current output)
7 Alarm output
* At user side you connect the seal to 0V

<[piguteiru] type (option)>
Plug type: SNW-1607-PCF
Application cable major diameter: φ6.6 - φ7.5
Application electric wire size: 0.5 Square mm or less