Exsenco U.S Contact For Santest

GYLT-T/GYLS-T

 

Photograph 3
As for GYLT-T and the GYLS-T probe former GYLT, in the GYLS probe zero points, it is something which can give full scale point output adjustment function. As for output adjustment using the precise driver from the adjustment hole which is provided in the connector adapter unit, it is possible to do simply.
After it ended adjustment, dustproof, it becomes waterproof structure (IP67) by the fact that the protective screw of attachment is installed. The sensor section in order former GYLT, to use the GYLS probe, high accuracy low has become electric power consumption.
There are 2 types of electric current output GYLT-T type and voltage output GYLS-T type.
3
3
3

Specifications

3
Precision Linearity ±0.025%FS TYP
Resolution Below 0.01%FS
Repeatability Below ±0.01%FS
Temperature characteristic Below 40ppm FS/℃
Output Electric current output [GYLT-T] 4 - 20mA or
20 - 4mA (below load resistance 500Ω)
Voltage output [GYLS-T] 0 - 10VDC or
10 - 0VDC (load current max5mA load resistance min2kΩ)
Supply power source DC24V±2V 0.05A
Scanning frequency 1kHz (standard)
Environmental characteristic Resisting pressure 35MPa (rod)
Category temperature range -20℃ - 80℃
Storage temperature range -40℃ - 80℃
Resistance swing 6G (or 40Hz2mmPP)
Shock resistant 50G (2msec)
Protective standard IP67 (10kPa and 30min)
* The above-mentioned precision is applied when it is above effective stroke 300mm.
* Output span of adjustable range is approximately ±3% of the full scale. 3

Type Variations

3
3
 
GYLT/GYLS-□□□□-B/A-□-□□-□
1 Effective stroke
3 max3000mm
2 Operational direction (to rod point when moving)
3 D: Increase operation R: Decrease operation
2 Installation screw
3 M: M24×P1.0 (standard) N: M18×P1.5 U: 3/4-16UNF
2 Shaft diameter
3 Blank: Φ 108: Φ 814: φ13.8
3

External Dimensions Drawing

3
3 ●GYLT-T/GYLS-T probe
GYLT/GYLS probe
3
Connector connection
1 DC24V
20 V
3 outputs (electric current or voltage)
4 COM
* The sealed braided line when at user side thing, however ground of ground there is influence of noise, is connection in 0V.
* Use connector: Omuron XS2C-D4S1 (straight type) or XS2C-D4S2 (light/write angle type)
* Application cable major diameter: φ5 - φ6 application electric wire size: 0.18 - 0.75mm2
* Output adjustment 0 driver of width 1.6mm is necessary. (In removal of protective screw 2.5mm hexagonal wrench necessary it is.)
* Output span of adjustable range is approximately ±3% of the full scale.
* Is only connector type. (There is no [piguteiru] type. )