Exsenco U.S Contact For Santest

GYMS

 

Photograph 4
The GYMS probe /GYMSC controller sees the improvement of precision e.g., with the sensor of compact [rokosutotaipu] which builds in the detection element of new system, it achieves below linearity ±0.025%FS. In addition, it has improved reliability with the probe protection standard IP-67 design. Connector type of option made the using good quality which surpasses to the cable gland type of standard possible.0 - 10V or it can obtain the analog signal 4 - 20mA with the combination of the GYMS probe and the GYMSC controller.
4
4
 
4

Specifications

4
Precision  Linearity Below TYP ±0.025%FS
Resolution Below 0.01%FS
Repeatability Below ±0.01%FS
Temperature characteristic ±40ppm FS/℃ (probe)
±50ppm FS/℃ (controller)
Output  Voltage output 0 - 10VDC or 10 - 0VDC
Load current Max 5mA, load resistance Min 2kΩ
Electric current output 4 - 20mA or 20 - 4mA
Load resistance Max 500Ω
Frequency characteristic Scanning frequency 1kHz (standard)
Power source and consumed electric current +24VDC 0.1A
Environmental characteristic Resisting pressure 35MPa (probe rod)
Category temperature range Probe -20℃ - +80℃
Controller 0℃ - +60℃
Storage temperature range -40℃ - +80℃
Resistance swing 6G (or 40Hz 2mmPP)
Shock resistant 50G (2msec)
Protective standard IP 67 (probe) (note)
Cable 1.5m (standard) (option Max100m)
4
* The above-mentioned precision is applied to the sensor above effective stroke 300mm.
* Input power source +12VDC type option selection it can receive. (However, output ±5V or is 0 - 5V to in stroke 200mm)
* Note) protective standard IP67 withstands the use 30 minutes to the depth of water 1m.
 (You cannot use for the use which it submerges continually)
 In addition, connector type waterproof efficiency is shown in fitting state of the connector.
4

Type Variations

4
4  
GYMS-□□□-□-□□
1 Effective stroke
4 300. 500. 700. 1000. 1500. 2000 (max3000mm)
2 Installation screw
4 J8: M20xP1 (standard)
L8: M16x2.0
N: M18xP1.5 (rod diameter φ10)
U: 3/4-16UNF (rod diameter φ10)
3 Cable removal
4 G * [piguteiru] type (standard) (* cable length (m): Standard 1.5) CN: Connector type
 
GYMSC-01-□-□□□□-□
1 Output
4 A: 0 - 10V B: 4 - 20mA C: In addition (bipolar and the like)
2 Effective stroke
4 300.500.700.1000.1500.2000
3 Operational direction (to rod point when moving)
4 D: Increase operation R: Decrease operation
 
CLMS-□□-□
1 Cable length (m)
4
2 Connector form
4 S: Straight type L: Angle type
4
4
4
* Please choose the magnet from No.2PN, No.φSPM and No.φLPM etc. (You cannot use No.2P and No.φ)
* As for output fine control of zero/full scale points it is possible to do with the controller front trimmer. (Adjustment range: ±3%FS)
4

External Dimensions Drawing

4
4 ●GYMS probe
4
4 Material probe head: SUS304 probe rod: SUS304
GYMS probe <Cable gland type (standard)> <Cable gland type (standard)>
GYMS probe <Connector type (option)> <Connector type (option)>
 Connector type
 XS2C-D4S1 (Omuron make)
GYMS probe <Angle connector type (option)> <Angle connector type (option)>
 Connector type
 XS2C-D4S2 (Omuron make)
4
4 ●GYMSC controller
GYMSC controller
4
4 - Magnet
4
4 No.2PN
(Holder material nylon 66) (color: White)
4
Magnet No.2PN 4
4 No.ΦSPM
(Holder material polyacetar)
4 No.ΦLPM
(Holder material polyacetar)
Magnet No.ΦSPM Magnet No.ΦLPM
4 4 4 4 4
4

Options

4
It can produce the effective stroke of the probe at the optional length of 30mm - 3000mm.
The connector can choose also angle type.
Output bipolar and reversal output etc is possible.