Exsenco U.S Contact For Santest

 

GY Series

 

01

2
The magneto-striction type level meter GY series is the level meter of the float type which utilizes magnetostriction phenomenon. In the magnetostriction line inside the sensor probe, with the magnetic built-in float which is moved alongside the sensor probe, the twisting strain occurs. Continual change of the liquid level high accuracy (below resolution 0.01%FS) is inspected by measuring the propagation delay time of the distortion, precision of the highest level actualization is actualized as a float type level meter. In addition, the wide to 30mm - 5000mm it can take effective measurement length, the sensor probe of optional length shortly with payment date can obtain.
2

02

2
The rod and the float of the sensor probe SUS304 (standard) or with 316, can use these materials for all liquids which do not corrode. In addition it is possible also with option to make SUS316L, Ti and the teflon etc. In addition, also sanitary specification and electrolytic polishing are possible. The category temperature range connection liquid section 350℃ continuous duty is possible with super early type. Furthermore use with the place and the outside where the liquid catches by designating the head section of the sensor probe as complete waterproof structure is possible.
2

03

2
As for IGY series intrinsically safe construction (explosion-proof sign: Exia K CT4) with we have become, you can use with most explosiveness gas atmosphere. Details the individual engineering data claim.
2

Specifications

2
GYcRP series
Precision Linearity Below TYP ±0.05%FS
Resolution Below 0.01%FS
Repeatability Below ±0.01%FS
Temperature characteristic
(Probe)
Below 0.005mn/℃+10ppm FS/℃
(Controller) ±20ppmFS/℃
Output output Voltage output 0 - 10VDC or 10 - 0VDC
Load current Max 5mA, load resistance Min 5k Ω
Electric current output 4 - 20mA or 20 - 4mA
Load resistance Max 500Ω
Alarm output Dry b contact point 1A30VDC
Speed output
(Option)
±10V (speed resolution 1%)
Frequency characteristic Scanning frequency 1kHz (standard)
Power source and consumed electric current ±15VDC type +15V±5% below 20mA
          -15V±5% below 40mA
+24VDC type +24V±5% below 350mA
Environmental characteristic Resisting pressure 350kgf/p (probe rod)
Category temperature range Probe -5℃ - +65℃
Controller 0℃ - +60℃
Storage temperature range -40 - +80℃
Resistance swing
Shock resistant
6G (or 40Hz 2mmPP)
50G (2msec)
Protective standard IP65 (probe)
Cable 1.5m (standard) (option Max200m)
2

* The above-mentioned precision is applied to the sensor above effective stroke 300mm.
* The controller has prepared also digital/serial output type.

2

External Dimensions Drawing

2
●GYcRP probe
Material probe head: Aluminum alloy probe head: SUS304
2
1